Electrodes, EasyCap, and Accessories
Gunjan Human Karigar offers a wide variety of electrodes and accessories. Because the
NeXus product series has active amplifiers built into the encoder, you will only
require our carbon coated electrode cables (with active shielding) for recording
electrophysiological signals. The EasyCap shown below offers an easy way to
record up to 32 channels of EEG with the NeXus-32. Sizes are from 36 to 62 cm.
The standard electrode configurations is the 10-20 system and supports up to 21
(uni-polar) EEG channels. Other configurations with more electrode positions can
be ordered at additional cost.
Product Information
TTrode3
Pregelled Triple-gel-Trode
This is a special pregelled surface EMG with combined positive,
negative and ground electrodes at 20 mm distances. This
self-adhesive electrode is for one-time use only. Ag/AgCl based.
Product Information
ArboEXG
Pregelled ECG/EKG/EMG
electrode
This is a pregelled surface EKG/EMG electrode with a good
price-performance ratio. This self-adhesive electrode is for
one-time use only. Ag/AgCl based. Strong adhesiveness. (not
suitable for
children)
Product Information
EasyCap-XX
Easy EEG cap for up
to 21 channels.
This is a high-quality and flexible EEG cap that uses the
special sintered ring-electrodes with carbon coating and active
shielding. Offers virtually (movement) artifact free EEG recording
with NeXus-32. Sizes from 36-62 cm. (in steps of 2 cm)
Product Information
Monoject-25
A set of 25 blunt
needles
This set of 25 blunt needles is used for filling the EasyCap
electrodes with the electrode-gel. Needles can be reused several
times. Prepare the skin with NuPrep before applying the gel.
Product Information
EL1020
10-20 EEG Paste
This is the standard EEG-paste for use with the NeXus-10 EEG and
SCP electrodes. Prepare the skin with NuPrep and apply the 10-20
Paste on the skin and on the EEG Electrodes. Suitable for use with
normal EEG and slow cortical potentials.
Product Information
ELNX-VAG
Pelvic Floor
(Vaginal) EMG sensor
This is a vaginal sensor for pelvic floor training with
NeXus-10. NeXus-10 is capable or recording and feeding back both
the raw EMG and the normal EMG amplitudes. This sensor is
restricted for use by a single person only. Require NX-MiniDin1
Product Information
NX-MiniDin1
NeXus-10 mini-din
adaptor cable
This cable is required when using the vaginal or rectal EMG
training sensor. It converts the mini-din plug on the sensor to a
single-EMG channel input on the NeXus-10. A ground connector is
included.
Product Information
EC-chinbelt
EasyCap chin-belt.
This is a (spare) chin-belt to be used with the EasyCap EEG
electrode cap. It is required to keep the EasyCap in place during
recording.
Product Information
MediTr100
Pregelled ECG/EKG/EMG
electrode
This is a special pregelled surface EKG/EMG electrode with a
very good price-performance ratio. This self-adhesive electrode is
for one-time use only. Ag/AgCl based. Normal adhesiveness.
Product Information
Blue2RT3
Reusable EEG/EMG
electrodes
This is a reusable surface EEG/EMG electrode with a good
price-performance ratio. This Ag/AgCl electrode can be used with
10-20 paste (EEG) for up to 10 times.
Product Information
Electrogel-16fl
Electrogel for the
EasyCap
Place the sintered ring electrodes on the EasyCap prepare the
skin with NuPrep of another preparation method. Then use the 10 ml
syringe with a blunt needle to fill each Ag/AgCl electrode with
this conductive gel.
Product Information
syringe10ml
A 10 ml syringe
This syringe is used to fill the sintered ring electrodes with
electrode-gel when they are mounted on the EasyCap. Requires the
blunt-needles to be ordered separately.
Product Information
ELNuPrep
NuPrep skin
preparation gel
This abrasive skin preparation gel is used to prepare the skin
for recording electrophysiological signals like EEG. (can be used
for EMG and ECG as well). It reduces the electrode-impedance and
optimizes the contact between the skin and the electrode.
Product Information
ELNX-Rectal
Rectal EMG training
Sensor
This is a rectal sensor for EMG training with the NeXus-10.
NeXus-10 is capable or recording and feeding back both the raw EMG
and the normal EMG amplitudes. This sensor is restricted for use
by a single person only. Requires NX-MiniDin1.
Product Information
NX-Adaptor1
NeXus-10 ->
NeXus-16/32 Adaptor
This is an adaptor cable for those people that want to use their
NeXus-10 auxiliary sensors (BVP,RSP, Skin Temp. and SC) on the
NeXus-16 or NeXus-32 as well. Not required when you do not use
NeXus-10.
Product Information
ELSC-Finger
SC/GSR finger
electrodes
This is a (spare) set of finger electrodes for the NeXus-10, 16
and 32 skin conductance sensor. This electrode can be used
multiple times. Based on Ag/AgCl electrode materials.